Demineralization (DM) is a crucial process for removing minerals and salts from water. As manufacturers, suppliers, and exporters of DM Water Treatment Plants in Pune, India, we offer innovative, reliable, cutting-edge solutions for various industries.
Configuration: Pretreatment + Cation + Anion (OR Membrane based). This type of DM plant is suitable when the conductivity requirement is less than 10-30 μmhos/cm. Note that for raw water TDS above 500 ppm, a membrane-based DM plant is preferred.
Configuration: Pretreatment + Cation + Anion (OR Membrane based) + Mixed Bed (MB). This DI water plant is used when the conductivity requirement is less than 1.0 μmhos/cm. This quality of water is required for most industrial applications.
Configuration: Pretreatment + Membrane + EDI. This type of plant is used when the conductivity requirement is less than 0.5 μmhos/cm. This quality of water is required for laboratory-grade or pharmaceutical applications.
Cost-Effective Models Variety of standard manual and automatic options available.
User-Friendly Design Easy to install, operate, and maintain.
Quality Assurance Pre-dispatch assembly checks ensure reliability.
Efficient Operation Single valve operation simplifies the process.
DM PLANT MODEL | Min Flowrate ( M3/hr) | Approx OBR* @ 500 PPM TDS |
eDM - 50 | 1 | 2500 |
eDM - 80 | 1.2 | 3750 |
eDM - 100 | 1.5 | 5000 |
eDM - 140 | 2.5 | 6000 |
eDM - 180 | 3 | 8750 |
eDM - 250 | 3.5 | 12500 |
eDM - 300 | 4 | 15000 |
eDM - 440 | 6 | 21000 |
eDM - 710 | 8.5 | 35000 |
eDM - 900 | 12 | 45000 |
eDM -1330 | 18 | 65000 |
eDM -2090 | 25 | 100000 |
OBR* - Output Between One Regeneration. Automatic and Manual regenerations models are available. Most of DM plants require the pretreatment like PSF, ACF, Cartridge Filter depend upon the input raw water quality. The chemicals like HCl and NaOH being used for the regeneration process.
• Flow rate : 50 to 80 Lit / hr.
• Space requirement : very compact-
1 m x 1m x 1.5 M
• Power : NIL, Min inlet pressure
0.5 kg/cm2
• Output TDS : Less that 10 ppm
• Output DM Qty. : 500 Lit at 100
ppm
• Best suitable when feed Water is corporation Water TDS < 100
ppm
• Flow rate : 50 to 80 Lit / hr.
• Space requirement : very
compact- 1 m x 1m x 1.5
• Power : NIL, Min inlet pressure
0.5 kg/cm2
• Output TDS : Less that 10 ppm TDS
• Output DM Qty. : 500 Lit at 100
ppm
• Best suitable when feed Water is corporation Water TDS < 100 ppm
• Flow rate : 500 to 600 Lit / hr.
• Space requirement : 1 m x 2 m
x 1.0 M
• Power : 0.5 HP
• Output TDS : Less that 10 ppm
• Output DM Qty. : 1350 Lit at 300 ppm TDS
• Best suitable when feed Water
is Borewell Water TDS < 300 ppm
Fully Atomatic Cabinet type Membrane + DI Models (RODI) - Available in 25 LPH, 50 LPH and 100 LPH models. The outlet water TDS < 1.0 ppm
Determine the characteristics of your raw water supply.
Identify specific water quality needs for your industry.
Customize the DM plant based on your parameters and budget
Install and commission your tailored DM water treatment solution.
SR # | Description | Your Comments |
1 | Company Name, Address, Contact Person name and Tel No | |
2 | Source of Water- Corporation/Lake/Well/Bore-well? | |
3 | Inlet Water pH, TDS, Hardness, Turbidity, etc. ( Detail report will be better) | |
4 | Usage Of DM Water- Any specific purpose? | |
5 | Output water Quality in Terms Of TDS, Conductivity required? (Detailed requisite parameters with limits would be better) | |
6 | Total quantity of of DM water required per day? | |
7 | Space availability in L x B x H ( In Meter) |